Today’s most critical Data Centers (DC), Internet Data Centers (IDC), Telecom hotels and Network Operations Centers (NOC) require levels of performance not achievable (for most businesses) a decade ago. Many of our clients cannot afford to experience a single data center failure in the foreseeable future. They require all adds, moves, deletes and system upgrades to be transparent to the end user/customer. Fortunately, the requirements can be met for reasonable investments. We have had considerable success in helping our clients achieve the performance they need to meet the commitments they must make to their customers.
Mechanical, electrical, plumbing, fire alarm, fire sprinkler design
Duplicate sites of 100,000ft2 each with computer room and 2.4 megawatts backup power
Engine generator and communication/security system with code blue stations
Five-9s availability, 60,000ft2 data center
Mechanical, electrical, plumbing, fire alarm and fire suppression design
50,000 sf data center with 4-story 300,000ft2 office building
Dual bus power structure, dual utility feeds, dual UPS, dual generators, redundant A/C systems, site automation and monitoring, site documentation and site testing
Mechanical, electrical, plumbing, and site lighting design
650,000 sf facility with computer room, offices, warehouse, manufacturing, generator plant
Mechanical, electrical, plumbing, and fire sprinkler design
20,000 fs computer room in 3-story 300,000 sf facility
Mechanical, electrical, plumbing, and fire protection design
2,500 sf computer room with redundant UPS systems for continuous availability
Mechanical, electrical, plumbing, and site lighting design
Flight simulators with computer rooms in 63,250 sf facility of classrooms and offices
Mechanical, electrical and plumbing design
1,400 sf computer room and backup generator in 26,600 sf facility
Mechanical and electrical design to add a 1200 SF raised floor area,
install new Liebert CRAC units with ability to expand for future needs,
addition of UPS module, and Automatic Transfer Switch (ATS).
Five-9s availability, 50,000ft2 data center
Mechanical, electrical, plumbing, fire alarm and fire suppression design
200,000ft2 office space with high reliability power and HVAC systems
Dual-bus power system
Redundant chiller systems
Site documentation and testing
Mechanical and electrical design
Mechanical, electrical, plumbing, and fire suppression design
Two 10,000ft2 computer rooms in 100,000ft2 office
Mechanical, electrical, plumbing, and fire suppression design
8,000ft2 computer room in 130,000ft2 office
UPS and standby generator and site monitoring
Mechanical, electrical and plumbing design
5,200 sf simulator bays with computer room
Mechanical, electrical and plumbing design
25,000 sf facility with computer room
Mechanical, electrical, and fire protection design
Re-design of existing data center
Mechanical, electrical, plumbing, and fire protection design
6,000 sf computer room
Data Center and Generator
Mechanical, electrical, plumbing and fire protection design
Mechanical, electrical and plumbing design
5,600 sf tenant improvement
600 sf network operations center with generator backup
4,300 sf computer room/lab on 2nd floor
790 sf computer room on 3rd floor
39,740 sf office
Mechanical, electrical and plumbing design
4,308 sf computer room and backup generator
Mechanical, electrical and plumbing design
6,020 sf sf data center
Mechanical, electrical, plumbing, and fire sprinkler design
1,500 sf data center
Mechanical, electrical and plumbing design
3,000 sf computer room expansion
Mechanical, electrical, plumbing, fire sprinkler, and site lighting design
1,600 sf computer room in 28,000 sf tenant improvement
Mechanical, electrical, plumbing, and fire sprinkler design
60,000 sf international hub and call center with 2,000 sf data center
Mechanical, electrical, plumbing, and fire sprinkler design
1,500 sf data center
Mechanical, electrical, plumbing, and fire sprinkler design
30,000 sf facility with computer room and generator
Mechanical, electrical, plumbing, and fire protection design
3,000 sf computer room expansion on 1st floor
6,000 sf computer room on 2nd floor
13,600 sf Tenant Improvement
Mechancial, electrical and plumbing design
4,441 sf computer room and 195 sf equipment room on 1st floor
Two equipment rooms of 130 sf each on 4th floor
22,079 sf office space
Mechanical, electrical, plumbing, and fire sprinkler design
700 sf data center expansion in an industrial facility
Mechanical, electrical, plumbing, and fire alarm design
20,000 sf office with computer room
Mechanical, electrical and plumbing design
70,000 sf tenant improvement with computer room
Mechanical, electrical and plumbing design
600 sf computer room in 14,000 sf office
Mechanical, electrical and plumbing design
900 sf computer engineering lab with 300 sf office
Mechanical, electrical and plumbing design
515 sf computer room in 4,000 sf office
Mechanical, electrical and plumbing design
450 sf computer room in 7,358 sf office
Mechanical, electrical and plumbing design
150 sf computer room
Mechanical, electrical and plumbing design
300 sf computer room in 3,592 sf tenant improvement
Mechanical, electrical and plumbing design
4-story 35,424 sf facility with computer room and generator
Mechanical, electrical and plumbing design of new data center office
Computer Room HVAC Evaluation
Mechanical, electrical, plumbing, and site lighting design
12,084 sf facility with computer room and basketball court
Mechanical, electrical and plumbing design
3,000 sf data center in 125,000 sf facility with rack storage, offices and cooler/freezer storage
Mechanical, electrical and plumbing design
600 sf computer room and generator set
Mechanical, electrical and plumbing design
20,335 sf facility – Add UPS and Power Distribution Equipment and A/C for computer room
Mechanical, electrical and plumbing design
Data Center
Boca Raton, FL
Electrical Load Study for Computer Room
Mechanical, electrical, plumbing, and fire sprinkler design
12,700 sf office with data center
Mechanical, electrical design
4,500 sf tenant improvement with 600 sf data center
Mechanical, Electrical, Plumbing and Fire Alarm for
HVAC redundancy for computer room
Boca Raton, FL
Electrical Load Study for Computer Room
Mechanical and Plumbing for 20,000 sf computer room
Mechanical, Electrical and Plumbing for 1,500 sf computer room
With FM-200 system
Mechanical, Electrical, Plumbing
Mechanical, Electrical and Plumbing for 500 sf computer room
Mechanical, Electrical and Plumbing for Computer Room and Control Room